Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13702789

- Product Categories
- Friendly Links
Information Name: | Human electrostatic discharge alarm device intrinsically safe plants supply |
Published: | 2015-05-26 |
Validity: | 60 |
Specifications: | Complete |
Quantity: | 8000.00 |
Price Description: | |
Detailed Product Description: | Human electrostatic discharge device CM-003 touch static elimination ball, its appearance is made of stainless steel tubes and stainless steel ball, it applies to the chemical industry, metallurgy, industry, oil, petrochemical, gas stations, electric power, electronics, railways, mining, gas, fireworks, computer room, luxury hotels, offices and other senior fire and explosion hazard potential medium of flammable and explosive environment. Circuit is basically the same principle and the other, its greatest feature is able to work in -50 ~ 100 ℃. Body static eliminator it is to adopt a passive circuit, static electricity on the human body to make use of the circuit, and finally to eliminate the electrostatic effect. Its features are: small size, light weight. No power. Easy to install. No sense to eliminate static electricity when other characteristics. Medical studies have proven: the accumulation of electrostatic hazards human health: some people allergic reactions, heart rhythm disorders, headaches, insomnia, and irritability and other symptoms, there are people Maofa Jian Li, mental stress. Afraid to touch metal objects. In addition, when the body accumulate electrostatic touch computer cause the computer to crash, electronics components breakdown, and other hazards ignite combustible technical indicators 1, the human body static voltage: V≤20KV (ball Φ100mm) 2, electrostatic discharge time: t ≤ 100mS (tube Φ63mm) 3, the maximum release current: I≤ 0.1mA (thickness 1.2mm numeral) 4, ambient temperature: 20 ℃ 5, humidity: ≤80% (40 ℃) 6, CM-003 Weight: 7.5kg Total height: 1.0m 2 test conditions and results of the human body static voltage: 18KV ambient temperature 20 ℃, fingers release time + 0.091s, the residual voltage is -10V fingers, the release time -0.090s, the residual voltage is -10V, palm release time + 0.084s residual voltage -9V, palm release time -0.082s, residual voltage -9V 2.1 static elimination time in line with ESD standard use and installation methods: CM-003-type installation method: CM-003 total height of one meter, with a base, First Φ10 screw set into the ground lug on, through the base is screwed onto the bottom of a stainless steel tube nut. Connected to the ground so that the installation is completed. Hand to touch the ball on the human body electrostatic discharge clean. Ground preferably not less than 0.3 square multi-strand lead wires to the ground, the other on the same parameters. There is a small hole in the tee, the hole has a static indicator, if there is static electricity in your body, simply touch a finger at the above metal balls (one second) can help eliminate the human body static electricity (lights off after about ). Clear night, the day is not obvious. If static electricity is less than 100V or no static electricity in the body, electrostatic indicator is not bright. Maintenance: Before installing the mobile white steel pipe to gently put, it is because there is within the original pipe circuit, do not enter the pipe debris, especially metal objects, such as metal objects into the circuit does not work properly. Because the ball and steel insulated from each other so we can not have other metal near the ball. 3 Installation Note 1. This device must be connected to the ground connection installation substance. 2. During the installation process must be able to meet the conditions to avoid fire caused by the construction and avoid accidents. 3. Before the installation must check whether the semiconductor body and joints touching damage occurred, prohibited the installation appears damaged point. 4. Each walk 25 meters in the body's normal process of moving, the human body static electricity will be higher than the minimum point of steam for oil energy (0.2mj), at intervals of 25 meters is recommended to install 一枚 This item 5. Keep in normal use Human touch body contact with the semiconductor 10-15 seconds, to achieve the purpose of human electrostatic safe release. 6. Keep clean touch-proof body electrostatic discharge during use. Company production, management products include: all kinds of explosion-proof tools, explosion toolbox, magnetic tools, special tools, static equipment, measurement tools, insulated tools, explosion-proof lighting tools, fire emergency supplies of oil spill pollution prevention tools. Inflammable and explosive materials proof metering kit, gas station explosion dedicated toolbox, toolbox depot special explosion-proof, gas-proof repair kit, mining explosion-proof emergency kit, oil storage tank explosion, fire emergency box, explosion-proof medicine first aid kit, explosion-proof power distribution room dedicated toolbox, toolbox trestle special explosion-proof, explosion-proof convenience box; proof emergency package; respirator; emergency lighting group; absorption felt, booms, dispersant spraying devices and other products. |
Admin>>>
You are the 11249 visitor
Copyright © GuangDong ICP No. 10089450, Botou City intrinsically safe equipment Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 11249 visitor
Copyright © GuangDong ICP No. 10089450, Botou City intrinsically safe equipment Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility